Description

Orion 12v-12v 30 AMP

Technical Specifications

Input Characteristics

Input Voltage Range

  • 12V models: 8-17V nominal input voltage
  • 24V models: 16-35V nominal input voltage
  • 48V models: 32-70V nominal input voltage

Under-Voltage Protection

  • 12V models: 7V shutdown, 7.5V restart
  • 24V models: 14V shutdown, 15V restart
  • 48V models: 28V shutdown, 30V restart

No-Load Input Current

  • 250-280W models: < 80mA
  • 360-400W models: < 80mA standby consumption

Output Specifications

Nominal Output Voltage

  • 12V output models: 12.2V nominal
  • 24V output models: 24.2V nominal
  • 48V output models: 48.2V nominal

Output Voltage Adjust Range

  • 12V models: 10-15V adjustable setpoint
  • 24V models: 20-30V adjustable setpoint
  • 48V models: 40-60V adjustable setpoint

Output Voltage Tolerance: +/- 0.2V regulation accuracy

Output Noise: 2 mV RMS ripple voltage

Continuous Output Current at 25°C

  • 12/12-18: 18A (216W)
  • 12/12-30: 30A (360W)
  • 12/24-10: 10A (240W)
  • 24/12-20: 20A (240W)
  • 24/24-12: 12A (288W)
  • 48/12-20: 20A (240W)
  • 48/24-16: 16A (384W)
  • 48/48-8: 8A (384W)

Maximum Output Current at 20% Reduced Voltage

  • 12/12-18: 25A peak
  • 12/12-30: 40A peak
  • 12/24-10: 15A peak
  • 24/12-20: 25A peak

Short-Circuit Output Current

  • 12/12-18: 40A maximum
  • 12/12-30: 60A maximum
  • 24/12-20: 50A maximum

Performance Characteristics

Conversion Efficiency

  • 250-280W models: 87-88% typical efficiency
  • 360-400W models: 87-89% typical efficiency at nominal load

Continuous Output Power at 25°C

  • 12/12-18: 280W
  • 12/12-30: 430W
  • 12/24-10: 280W
  • 24/12-20: 300W
  • 48/12-20: 280W

Continuous Output Power at 40°C

  • 12/12-18: 220W derated
  • 12/12-30: 360W derated
  • 12/24-10: 240W derated
  • 24/12-20: 240W derated

Charging Algorithm

Charge Stages: Bulk – Absorption – Float (3-stage adaptive algorithm)

Bulk Phase: Constant current delivery until absorption voltage reached

Absorption Time:

  • Lead-acid: 2 hours default, automatically extended after deep discharge
  • Lithium: Fixed duration configurable

Float Voltage: Reduced maintenance voltage for long-term connection

Alternative Mode: Fixed output voltage (configurable, bypasses multi-stage algorithm)

Isolation and Protection

Galvanic Isolation: 200 VDC between input, output, and chassis

Protection Rating: IP43 (solid objects > 1mm, water spray up to 60° from vertical)

Thermal Protection: High-temperature current derating prevents overheating

Short-Circuit Protection: Automatic current limiting during fault conditions

Reverse Polarity Protection: Input fuse (non-replaceable) protects against reverse connection

Control and Connectivity

Bluetooth: Integrated Bluetooth Low Energy for wireless configuration

VictronConnect App: iOS and Android mobile application for monitoring and parameter adjustment

Remote On/Off: Two-pole connector accepts switch or relay contact

Alternative Control: H-terminal enables battery plus or chassis-switched operation

GX Device Compatible: Integration with Victron GX devices for VRM portal access

Power Supply Mode: Output voltage user-settable via Bluetooth

Environmental Specifications

Operating Temperature Range: -20°C to +55°C (derate 3% per °C above 40°C)

Humidity: Maximum 95% non-condensing

Altitude: Performance maintained up to 2000m above sea level

Physical Specifications

Connection Type: Screw terminals (no special tools required)

Maximum Cable Cross-Section: 16mm² (AWG6)

Dimensions (H × W × D)

  • 250-280W models: 130 × 186 × 70mm (5.1 × 7.3 × 2.8 inches)
  • 12V input/output 360-400W models: 130 × 186 × 80mm (5.1 × 7.3 × 3.2 inches)
  • Other 360-400W models: 130 × 186 × 70mm (5.1 × 7.3 × 2.8 inches)

Weight

  • 250-280W models: 1.3kg (3 lb)
  • 12V input/output 360W models: 1.8kg (4 lb)
  • Other 360W models: 1.6kg (3.5 lb)

Compliance Standards

Safety Standards: EN 60950

Emission/Immunity: EN 61000-6-3, EN 55014-1 / EN 61000-6-2, EN 61000-6-1, EN 55014-2

Automotive Directive: ECE R10-5

Protection Category: IP43 (electronic components), IP22 (connection area)