Orion 12v-12v 30 AMP
Technical Specifications
Input Characteristics
Input Voltage Range
- 12V models: 8-17V nominal input voltage
- 24V models: 16-35V nominal input voltage
- 48V models: 32-70V nominal input voltage
Under-Voltage Protection
- 12V models: 7V shutdown, 7.5V restart
- 24V models: 14V shutdown, 15V restart
- 48V models: 28V shutdown, 30V restart
No-Load Input Current
- 250-280W models: < 80mA
- 360-400W models: < 80mA standby consumption
Output Specifications
Nominal Output Voltage
- 12V output models: 12.2V nominal
- 24V output models: 24.2V nominal
- 48V output models: 48.2V nominal
Output Voltage Adjust Range
- 12V models: 10-15V adjustable setpoint
- 24V models: 20-30V adjustable setpoint
- 48V models: 40-60V adjustable setpoint
Output Voltage Tolerance: +/- 0.2V regulation accuracy
Output Noise: 2 mV RMS ripple voltage
Continuous Output Current at 25°C
- 12/12-18: 18A (216W)
- 12/12-30: 30A (360W)
- 12/24-10: 10A (240W)
- 24/12-20: 20A (240W)
- 24/24-12: 12A (288W)
- 48/12-20: 20A (240W)
- 48/24-16: 16A (384W)
- 48/48-8: 8A (384W)
Maximum Output Current at 20% Reduced Voltage
- 12/12-18: 25A peak
- 12/12-30: 40A peak
- 12/24-10: 15A peak
- 24/12-20: 25A peak
Short-Circuit Output Current
- 12/12-18: 40A maximum
- 12/12-30: 60A maximum
- 24/12-20: 50A maximum
Performance Characteristics
Conversion Efficiency
- 250-280W models: 87-88% typical efficiency
- 360-400W models: 87-89% typical efficiency at nominal load
Continuous Output Power at 25°C
- 12/12-18: 280W
- 12/12-30: 430W
- 12/24-10: 280W
- 24/12-20: 300W
- 48/12-20: 280W
Continuous Output Power at 40°C
- 12/12-18: 220W derated
- 12/12-30: 360W derated
- 12/24-10: 240W derated
- 24/12-20: 240W derated
Charging Algorithm
Charge Stages: Bulk – Absorption – Float (3-stage adaptive algorithm)
Bulk Phase: Constant current delivery until absorption voltage reached
Absorption Time:
- Lead-acid: 2 hours default, automatically extended after deep discharge
- Lithium: Fixed duration configurable
Float Voltage: Reduced maintenance voltage for long-term connection
Alternative Mode: Fixed output voltage (configurable, bypasses multi-stage algorithm)
Isolation and Protection
Galvanic Isolation: 200 VDC between input, output, and chassis
Protection Rating: IP43 (solid objects > 1mm, water spray up to 60° from vertical)
Thermal Protection: High-temperature current derating prevents overheating
Short-Circuit Protection: Automatic current limiting during fault conditions
Reverse Polarity Protection: Input fuse (non-replaceable) protects against reverse connection
Control and Connectivity
Bluetooth: Integrated Bluetooth Low Energy for wireless configuration
VictronConnect App: iOS and Android mobile application for monitoring and parameter adjustment
Remote On/Off: Two-pole connector accepts switch or relay contact
Alternative Control: H-terminal enables battery plus or chassis-switched operation
GX Device Compatible: Integration with Victron GX devices for VRM portal access
Power Supply Mode: Output voltage user-settable via Bluetooth
Environmental Specifications
Operating Temperature Range: -20°C to +55°C (derate 3% per °C above 40°C)
Humidity: Maximum 95% non-condensing
Altitude: Performance maintained up to 2000m above sea level
Physical Specifications
Connection Type: Screw terminals (no special tools required)
Maximum Cable Cross-Section: 16mm² (AWG6)
Dimensions (H × W × D)
- 250-280W models: 130 × 186 × 70mm (5.1 × 7.3 × 2.8 inches)
- 12V input/output 360-400W models: 130 × 186 × 80mm (5.1 × 7.3 × 3.2 inches)
- Other 360-400W models: 130 × 186 × 70mm (5.1 × 7.3 × 2.8 inches)
Weight
- 250-280W models: 1.3kg (3 lb)
- 12V input/output 360W models: 1.8kg (4 lb)
- Other 360W models: 1.6kg (3.5 lb)
Compliance Standards
Safety Standards: EN 60950
Emission/Immunity: EN 61000-6-3, EN 55014-1 / EN 61000-6-2, EN 61000-6-1, EN 55014-2
Automotive Directive: ECE R10-5
Protection Category: IP43 (electronic components), IP22 (connection area)