Alarm system concept |
Wired modular system |
Wired modular system |
Wired modular system |
On-board wired zones |
8 |
8/16 (doubling) |
8/16 (doubling) |
2-wire smoke detector input |
– |
– |
– |
On-board wireless zones |
– |
– |
– |
Maximum zones in system |
8 |
16 |
32 |
On-board PGM |
3 |
3 |
3 |
Maximum PGM in system |
8 |
16 |
16 |
User + installer codes |
5+1 |
31+1 |
31+1 |
Duress code |
X1, X2, X3, X4 (when X4 = X4 + 1) |
Defaulting user code |
Yes |
Yes |
Yes |
Key switch zone |
– |
Yes |
Yes |
Partitions |
4 |
4 |
4 |
“Shared” partition (common area) |
– |
Yes |
Yes |
System timers |
– |
16 |
16 |
Maximum keypads/modules in system |
7 |
15 |
15 |
Event log buffer |
512 |
512 |
512 |
PSTN communicator |
In-built |
In-built |
In-built |
In-built interface for backup communicator |
TTL Serial |
TTL Serial |
TTL Serial |
Data bus protocol |
KRBUS |
KRBUS |
KRBUS |
Total phone numbers: CMS reporting + personal dialing |
4 |
4 |
4 |
Maximum phone numbers for personal dialing |
Up to 4 |
Up to 4 |
Up to 4 |
Maximum phone numbers for CMS reporting |
Up to 4 |
Up to 4 |
Up to 4 |
Reporting protocol |
Contact ID |
Contact ID, 4×2 |
Contact ID, 4×2 |
Voice guide for system control over PSTN |
– |
PAS816 V3 only |
PAS832 V3 only |
Voice guide for system programming over PSTN |
– |
PAS816 V3 only |
PAS816 V3 only |
“Roller” detector type |
– |
Yes |
Yes |
“Vibration” detector type |
Yes |
Yes |
Yes |
“Vibration” zone speed (sensitivity) |
0.01 – 0.25 sec. |
0.01 – 0.25 sec. |
0.01 – 0.25 sec. |
Normal zone speed (sensitivity) |
0.1 – 2.5 sec. |
0.1 – 2.5 sec. |
0.1 – 2.5 sec. |
Zone loop (detector) type |
NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration |
NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller |
Arming mode |
Away, Max Away, Night, Stay. |
Zone definition |
Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control;
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes |
Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm |
Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definition |
Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes |
Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification |
Rated voltage of power supply (AC) |
~20 V |
~20 V |
~20 V |
Minimum AC voltage
(note: ~16 V input voltage lets control panel to generate max 0.7 A output current) |
~16 V |
~16 V |
~16 V |
Maximum AC voltage
(Note: higher than ~22 V voltage can damage control panel) |
~22 V |
~22 V |
~22 V |
Maximum long term output current of control panel
(I+AUX + I+BELL + I+PGM + battery charge): |
≤1.2 A |
≤1.5 A |
≤1.5 A |
Maximum current of slow blowing fuse used in primary AC |
250 mA |
250 mA |
250 mA |
Maximum AC power consumption |
150 mA |
150 mA |
150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs |
12 V |
12 V |
12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs |
13.9 V |
13.9 V |
13.9 V |
Maximum current out of +AUX |
+0.8 A |
+1 A |
+1 A |
Maximum current out of +BELL |
+0.8 A |
+2 A |
+2 A |
Maximum current into -PGM |
-0.05 A |
-0.05 A |
-0.05 A |
Maximum current out of +PGM |
+0.8 A |
+0.9 A |
+0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX |
Electronic |
Electronic |
Electronic |
Battery charge, +BELL, +AUX current measurement |
– |
Yes |
Yes |
Failed (waste) backup battery disconnection |
– |
Yes |
Yes |
Maximum battery charging current |
+0.4 A |
+0.4 A |
+0.4 A |
Maximum current of fast blowing fuse used in battery circuit |
3.15 A |
3.15 A |
3.15 A |
Control panel disconnect battery when it’s voltage less than |
9.5 V |
9.5 V |
9.5 V |
Recommended backup battery |
12 V, 7 Ah / 20 Hr |
12 V, 7 Ah / 20 Hr |
12 V, 7 Ah / 20 Hr |
Operational compliance |
+EN50131, Grade2 |
+EN50131, Grade2 |
+EN50131, Grade2 |
Overall dimensions W x H in mm |
145 x 77 |
145 x 77 |
145 x 77 |
Environmental compliance |
ROHS |
ROHS |
ROHS |
Operating temperature |
-10oC up to +50oC |
Production status |
In production |
V2 discontinued,
V3Â in production |
V2Â discontinued,
V3Â in production |
Latest firmware version |
v0.03 |
V2: |
Reviews
There are no reviews yet.