Description

C TEC 2 Zone FP fire panel non-expandable

FP 2 Zone Conventional Fire Alarm Panel delivers comprehensive fire detection and alarm control for small to medium commercial buildings, providing reliable life safety protection through advanced conventional fire alarm technology. This professional-grade Model FF382-2 combines robust construction with installer-friendly design, ensuring dependable fire protection while simplifying installation and maintenance procedures for certified fire alarm technicians.

Engineered for commercial applications where fire safety cannot be compromised, this conventional fire alarm panel integrates dual zone monitoring with comprehensive sounder control, maintaining the reliability and performance standards demanded in professional fire protection systems while offering the flexibility required for diverse building configurations.

Why the FP 2 Zone Conventional Fire Alarm Panel Excels in Fire Safety Applications

Traditional basic fire alarm systems often lack the comprehensive monitoring and fault detection capabilities required for professional installations. The FP 2 Zone Conventional Fire Alarm Panel eliminates these limitations through advanced conventional technology that provides detailed system status monitoring, comprehensive fault detection, and reliable operation under demanding conditions.

This fire alarm control system delivers critical safety advantages including separate fault indication, flexible sounder control, and comprehensive system monitoring. Unlike basic alarm systems that compromise functionality for simplicity, this professional panel maintains full fire safety compliance while providing the advanced features required for modern commercial fire protection installations.

Technical Specifications and Fire Safety Performance

Advanced Fire Detection Technology

  • Dual zone capacity: Two conventional detector zone circuits with 500m maximum length per circuit
  • Device support: Up to 20 detectors per zone (maximum 2mA detector current)
  • Conventional compatibility: Compatible with virtually all conventional fire detectors including C-TEC ActiV range
  • Manual call point support: Unlimited manual call points with 470-680Ω resistor values
  • Head-out monitoring: Optional BF378M module support for enhanced monitoring capabilities
  • End-of-line monitoring: 6800Ω ±5% tolerance resistors for circuit supervision

Professional Sounder Control

  • Dual sounder circuits: Two conventional sounder circuits with 500m maximum length per circuit
  • Maximum output current: 800mA total output to all sounder circuits with 1A fuse protection
  • Class change functionality: Non-latching class change sounder output for evacuation control
  • Auxiliary relay: Onboard 1A 30VDC relay following sounder operation
  • Optional expansion: Additional relays available via expansion looms for enhanced control
  • Flexible operation modes: Latching fire and non-latching fault outputs via optional expansion

Robust Construction and Power Management

  • Heavy-duty enclosure: Robust metal construction with lift-off lid and secure base connections
  • Power supply specifications: 230V 50/60Hz mains with 27V nominal internal supply
  • Battery backup: Space for 2 x 12V 2.3Ah VRLA batteries in series configuration
  • Low quiescent current: 40mA standby consumption for efficient battery operation
  • IP30 rating: Professional enclosure protection for indoor installations
  • Compact dimensions: 322W x 267H x 92D mm for flexible mounting options

Commercial Fire Safety Applications

The FP 2 Zone Conventional Fire Alarm Panel serves critical fire protection needs across diverse commercial environments where reliable fire detection and alarm control directly impact occupant safety and regulatory compliance. Fire safety engineers, building managers, and certified installers frequently specify this panel for applications requiring dependable conventional fire alarm technology with professional-grade features.

Commercial Building Applications

  • Small office buildings: Comprehensive fire protection for professional office environments
  • Retail establishments: Customer and staff safety protection in commercial retail spaces
  • Restaurant and hospitality: Kitchen and dining area fire detection with specialized sounder control
  • Medical facilities: Patient safety fire protection in clinics and small healthcare facilities
  • Educational buildings: Classroom and administrative area fire protection systems
  • Warehouse facilities: Storage area fire detection with high-output sounder systems
  • Manufacturing plants: Production area fire protection with industrial-grade reliability

Specialized Installation Environments

  • Historic buildings: Fire protection systems preserving architectural integrity
  • Multi-tenant buildings: Zone-specific fire protection for individual occupancies
  • Religious facilities: Congregation safety with discreet fire protection systems
  • Community centers: Public facility fire protection meeting accessibility requirements
  • Residential care facilities: Enhanced fire protection for vulnerable occupants
  • Agricultural buildings: Barn and storage facility fire protection systems

System Integration Applications

  • Building management integration: Fire alarm integration with HVAC and access control systems
  • Repeater panel connectivity: Up to 3 repeaters with 200m maximum cable length
  • Expansion capabilities: Optional relay modules for lighting, HVAC, and door control
  • Emergency lighting integration: Coordination with emergency evacuation lighting systems
  • Security system integration: Fire alarm integration with security and access control

Compliance and Safety Standards

The FP 2 Zone Conventional Fire Alarm Panel meets comprehensive fire safety standards ensuring regulatory compliance and reliable operation in commercial fire protection applications. Professional installation and system design must adhere to applicable fire safety codes and standards.

Regulatory Compliance Standards

  • BS5839-4 compliance: Designed to meet British Standard requirements for fire alarm systems
  • Professional installation: Certified fire alarm technician installation required for compliance
  • Code compliance: Local fire safety code adherence for commercial installations
  • Inspection requirements: Regular testing and maintenance for continued compliance
  • Documentation: Comprehensive installation and maintenance documentation provided

Safety Feature Integration

  • Comprehensive fault monitoring: Separate indicators for open circuit, short circuit, sounder, and power faults
  • Zone isolation capability: Individual zone isolation for maintenance without system shutdown
  • Test functions: Built-in testing capabilities for system verification and maintenance
  • Manual override controls: Emergency evacuation and alarm silencing functions
  • Engineer access: Keyswitch protection for system configuration and maintenance functions

Professional Installation and Configuration

Certified fire alarm technicians appreciate the FP 2 Zone Conventional Fire Alarm Panel for its installer-friendly design and comprehensive configuration options. The panel’s design accommodates various installation requirements while maintaining optimal fire safety performance and regulatory compliance.

Installation Requirements

  • Mounting specifications: Robust mounting system with optional FF379 bezel for semi-flush installation
  • Environmental conditions: -5°C to +40°C operating temperature with 95% maximum relative humidity
  • Power requirements: 230V 50/60Hz mains supply with battery backup provision
  • Cable specifications: Appropriate fire-rated cables for zone and sounder circuits
  • Clearance requirements: Adequate access for maintenance and testing procedures
  • Documentation: Complete installation records for regulatory compliance

System Configuration Options

Professional installation includes comprehensive system programming including zone assignments, call point configuration, sounder delay settings, and auxiliary output programming. The FP 2 Zone Conventional Fire Alarm Panel provides flexible configuration options allowing customization for specific building requirements and fire safety strategies.

Expansion and Integration Capabilities

The panel supports various expansion options including fault relay modules (FF374FR), fire relay modules (FF374FDR), delay timer modules (FF374DT), and auxiliary input/output looms (FF374X). These expansion options enable integration with building systems while maintaining fire safety functionality.

Maintenance and System Reliability

Fire safety professionals rely on the FP 2 Zone Conventional Fire Alarm Panel for applications where system reliability directly impacts occupant safety. The panel incorporates comprehensive self-monitoring and diagnostic features ensuring continued reliable operation throughout its service life.

Diagnostic and Monitoring Features

  • Comprehensive status indication: Visual indicators for all system conditions and faults
  • Separate fault identification: Individual indicators for different fault types enable rapid troubleshooting
  • Battery monitoring: Continuous battery condition monitoring with low battery indication
  • Circuit supervision: End-of-line monitoring ensures circuit integrity and device connectivity
  • Test capabilities: Built-in testing functions for routine maintenance and inspection

Preventive Maintenance Requirements

Regular system testing includes detector function verification, sounder operation testing, battery condition assessment, and circuit continuity verification. Professional maintenance ensures continued regulatory compliance and optimal fire safety performance.

Quality Assurance and Professional Support

Manufacturing standards for this fire alarm panel emphasize long-term reliability and consistent performance under demanding commercial conditions. Comprehensive quality control procedures include environmental testing, electrical safety verification, and fire safety standard compliance to ensure adherence to international fire protection requirements.

Professional Documentation and Support

  • Comprehensive manuals: Detailed installation, operation, and maintenance documentation
  • Technical support: Professional technical assistance for installation and troubleshooting
  • Expansion documentation: Complete instructions for optional modules and system expansion
  • Compliance certification: Documentation supporting regulatory compliance requirements
  • Training resources: Professional training materials for certified technicians

Professional Recommendations and Fire Safety Benefits

Fire safety consultants and certified alarm technicians frequently recommend the FP 2 Zone Conventional Fire Alarm Panel for commercial installations requiring reliable conventional fire alarm technology with professional-grade features. The panel’s combination of robust construction, comprehensive monitoring capabilities, and flexible expansion options makes it essential for modern commercial fire protection where occupant safety and regulatory compliance cannot be compromised.

Building owners and facility managers report improved fire safety confidence and reduced maintenance requirements following installation of these professional fire alarm panels, particularly in applications where previous basic systems failed to provide adequate monitoring capabilities or suffered reliability issues under demanding commercial operating conditions.