Description

C-TEC XFP two loop 32 zone addressable fire alarm panel

C-TEC XFP two loop 32 zone addressable fire alarm panel represents a significant advancement in addressable fire alarm technology, combining C-TEC’s proven reliability with cutting-edge CAST (C-TEC Addressable System Technology) protocol. This sophisticated fire panel delivers unmatched performance for buildings requiring comprehensive fire detection and alarm capabilities.

Built on decades of fire safety expertise, the XFP502/CA transforms how facilities approach fire protection. C-TEC’s engineers designed this system through extensive research and development, ensuring compliance with stringent EN54-2, EN54-4, and EN54-13 standards while delivering practical solutions for real-world installations.

Technical Excellence Meets Practical Application

Advanced Loop Architecture

The XFP502/CA features two independently operated loop drivers, each supporting up to 255 CAST devices with robust 40V 450mA power output. This architecture enables installers to create comprehensive fire detection networks spanning up to 1KM per loop, accommodating large commercial and industrial facilities.

Professional fire safety engineers appreciate the panel’s distributed intelligence approach, where individual devices make autonomous decisions to accelerate emergency response times. This design philosophy reduces system response delays that can prove critical during actual fire emergencies.

Network Scalability and Integration

System integrators can connect up to eight XFP502/CA panels via RS485 networking, creating expansive fire safety networks suitable for multi-building campuses or large facilities. Each networked panel maintains independent operation while sharing critical information across the system.

The panel’s ENVISION IoT compatibility enables remote monitoring and management through cloud-based platforms, allowing facility managers to oversee fire safety systems from anywhere. This connectivity supports proactive maintenance scheduling and rapid fault identification.

Professional Installation Advantages

Flexible Addressing Options

The XFP502/CA offers two addressing methods to suit different installation preferences:

  • Automatic addressing through the main panel interface
  • Manual programming using C-TEC’s handheld programmer/device tester
  • Multi-level addressing system facilitates easy device additions
  • Swapped device identification simplifies maintenance procedures

Comprehensive Input/Output Configuration

Professional installers benefit from extensive connectivity options including two programmable conventional sounder circuits, multiple relay outputs with voltage-free changeover contacts, and flexible input configurations. These features enable integration with existing building management systems and specialized fire suppression equipment.

Operational Intelligence and User Experience

Advanced Fault Management

The XFP502/CA provides geographical fault location capabilities, identifying short and open circuit problems with precision. Each CAST device includes integrated short circuit isolation, maintaining system integrity even when individual components experience failures.

The panel’s contamination level adjustments and earth fault monitoring ensure reliable operation in challenging environmental conditions. These features prove particularly valuable in industrial settings where dust, humidity, or electromagnetic interference might affect system performance.

Intuitive Interface Design

The two-line, 40-character backlit display provides clear system status information, while 32 individual zone LEDs offer immediate visual confirmation of detector states. Combined keypad/keyswitch access controls protect system configuration while enabling authorized personnel to perform necessary operations efficiently.

Certification and Compliance Assurance

Rigorous Testing Standards

The XFP502/CA holds dual certifications from LPCB (EN54-2/4) and Kiwa Telefication (EN54-13), demonstrating compliance with European fire safety standards. These certifications provide assurance for consulting engineers specifying fire systems for regulated buildings.

C-TEC’s UK-based manufacturing ensures consistent quality control and rapid technical support. The company’s established reputation in fire safety equipment provides additional confidence for long-term system reliability.

Technical Specifications Summary

Power Requirements:

  • Mains supply: 230V 50/60Hz
  • Internal power: 27Vdc nominal
  • Battery backup: 2 x 12V 7Ah VRLA
  • Total output current: 3A maximum

Loop Capabilities:

  • Maximum devices per loop: 255
  • Loop output current: 450mA at 40V
  • Maximum loop length: 1KM
  • Protocol: C-TEC CAST

Physical Specifications:

  • Dimensions: 410W x 250H x 80D mm
  • Weight: 4.5kg (without batteries)
  • Operating temperature: -5°C to +40°C
  • IP30 rated enclosure

Applications and Market Suitability

The XFP502/CA serves diverse facility types including commercial offices, educational institutions, healthcare facilities, and light industrial buildings. Its scalable architecture accommodates both standalone installations and complex networked systems.

Fire safety consultants frequently specify this panel for retrofit projects where existing infrastructure requires integration with modern addressable technology. The system’s backward compatibility and flexible configuration options simplify upgrades from conventional fire alarm systems.

For new construction projects, the XFP502/CA provides foundation-level fire protection that can expand as building requirements evolve. Its networking capabilities ensure future system growth without requiring complete panel replacement.


The XFP502/CA represents C-TEC’s commitment to advancing fire safety technology through innovative engineering and proven reliability. Contact certified fire safety professionals to determine if this advanced addressable panel meets your specific building protection requirements.