Asenware AW-CFP2166-2 fire Alarm panel

KSh27,000.00

Description

Asenware AW-CFP2166-2 fire Alarm panel proftech

Asenware AW-CFP2166-2 fire Alarm panel is a conventional 2 zone fire panel has 2 level control mode by a lock, fire and fault signal output, optical GSM module for fire alarm by SMS, 2 general sounders output, battery low protection function, silence button to stop buzzer and sounders, each zone can be disable by a button, battery not included.

Asenware AW-CFP2166-2 fire Alarm panel description

AW-CFP2166 series conventional fire alarm control panel is designed based on EN54 part 2&4 standard.

2. It has 2 level control mode by a lock

3. It has 24VDC and 5VDC power supply output.

4.  Each zone  has 1 circuit detectors input .

5.  Each zone can be disable by a button.

6. It is modularized design, the fire panel can extend from 1 zone to 32 zones easily.

7. It has FIRE and FAULT signal output and 2 general sounders output.

8. It has RESET button to reset the panel  and SILENCE button to stop BUZZER and SOUNDERS.

9. It has EVACUATE button to start a manual fire alarm immediately.

10. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

11.  Fire alarm panel has an optional GSM module for fire alarm by SMS .

12.  Fire alarm control panel  is economic, user-friendly and easy maintenance.

uilding/8 zone conventional fire alarm control Panel

Asenware AW-CFP2166-2 fire Alarm panel description Features

ITEM 1 Zone panel 2 Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. of fire alarm conctrol panel AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification conventional fire alarm panel’  Power specification
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification   conventional fire alarm panel’ Detector circuit specification
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

conventional fire alarm control panel

End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maximum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit

fire alarm control panel

Sounder circuit specification    fire alarm control panel  Sounder circuit specification
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses  fire alarm control panel    conventional fire alarm panel  Fuses
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output   fire alarm control panel     conventional fire alarm panel output
Output type NC and NO relay
Maximum current 100mA
Connection block    fire alarm control panel  Connection block
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight    control panel
   fire alarm control panel  Size and weight
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg

12.5kg

Reviews

There are no reviews yet.

Be the first to review “Asenware AW-CFP2166-2 fire Alarm panel”

Your email address will not be published. Required fields are marked *